??Chinese Fuel Dispenser Verification Regulation
China's fuel dispenser verification regulations are primarily governed by JJG 443-2023《Chinese Fuel Dispenser Verification Regulation: Key Overview》 (Verification Regulation for Fuel Dispensers, Trial Implementation), which replaced the older JJG 443-2015 version. Below is a detailed breakdown of its core requirements and updates:
1. Scope and Applicability
? Applicable Equipment: Fuel dispensers with a maximum flow rate ≤200 L/min used for vehicle refueling.
? Regulatory Scope: Covers initial verification, subsequent verification, and in-use inspections .
2. Key Technical Requirements**
(1) Metrological Performance
? Maximum Allowable Error: ±0.30% for volume measurement.
? Repeatability: ≤0.10% across all flow rates.
? Payment Accuracy: Error between displayed amount and actual volume × price must be ≤ minimum payment variable .
(2) Structural and Safety Features
? Anti-Tampering: Mandatory self-locking function to disable dispensing if pulse rate or volume anomalies are detected.
? Component Consistency: Flow measurement transducers, encoders, and control boards must match type-approval documentation.
? Software Identification: Displays or outputs software version identifiers for traceability .
(3) New Structural Mandates
? Separate Flow Paths: No shared flow measurement transducers for multiple hoses.
? Explosion-Proof Design: Required for hazardous environments .
3. Verification Procedures
(1) Initial Verification
? Flow Points Tested: Q1 (max flow) and Q2 (second flow) at 3 measurements each.
? Adjustments: Allowed if errors exceed ±0.30%, followed by re-testing .
(2) Subsequent Verification
? Cycle Stability: If cycle stability (error/max allowable error) >2.0, the dispenser is deemed non-compliant.
? Adjustments: Permitted only if cycle stability ≤2.0 .
(3) In-Use Inspections
? Software Checks: Validate software identifiers via handheld terminals.
? Locking Mechanisms: Test self-locking functions for unauthorized modifications .
4. Compliance and Enforcement
? Certification Marks: Mandatory CPA (China Metrology Certification) labels on dispensers.
? Inspection Period: Typically ≤6 months.
? Penalties: Non-compliant dispensers receive inspection notices and may be sealed until rectified . 5. International Comparisons
? OIML R117: JJG 443-2023 aligns with OIML R117:2019 (Dynamic Measuring Systems for Liquids) but imposes stricter requirements, such as higher stability thresholds .
? ISO Standards: Components (e.g., nozzles, hoses) must meet ISO/CE certifications .
6. Challenges and Updates
? Technical Upgrades: Transition to digital payment systems and real-time data monitoring.
? Environmental Compliance: Stricter emission controls and energy efficiency standards .
Accessing the Regulation
? Official Document: Available through China’s National Market Supervision Administration (SAMR).
? Translation: China fuel dispenser (https://www.cnruijia.com),professional fuel dispenser manufacturer.
For detailed implementation guidelines, refer to the full text of JJG 443-2023 or contact certified calibration laboratories in China.